Sku: PE1324G-AX
Brand: ATEN
Category: KVM Over IP
Shipping Information
Availability: On Order
On Order - These items are sourced upon request and may take longer to deliver. We will confirm availability once your order is received, as some products may occasionally be discontinued or unavailable.
Shipping Calculator
Find
The PE1324 Energy PDU offers 24 AC outlets and a space-saving 0U rack mount design, perfect for efficiently managing power in server rooms. Available in IEC or NEMA socket configurations, it integrates with the EC1000 Energy Box for real-time current monitoring and remote environmental condition management.
100% Guarantee Safe Checkout
Description
Manufacture: Aten | Model: PE1324G-AX
Function | PE1324B | PE1324G |
Electrical | ||
Nominal Input Voltage | 100 – 240 VAC | 100 – 240 VAC |
Maximum Input Current | 30A(Max) | 32A(Max) |
Input Frequency | 50-60 Hz | 50-60 Hz |
Input Connection | NEMA L6-30P | IEC 60309 32A |
Input Power | 6240 VA(Max) | 7360 VA(Max) |
Outlet Type | Total: 24 x IEC320 C13 Bank1: Outlet 1 – 12; 12 x C13 Bank2: Outlet 13 – 24; 12 x C13 |
Total: 24 x IEC320 C13 Bank1: Outlet 1 – 12; 12 x C13 Bank2: Outlet 13 – 24; 12 x C13 |
Nominal Output Voltage | 100 – 240 VAC | 100 – 240 VAC |
Maximum Output Current (Outlet) | 15A(Max) | 10A(Max) |
Maximum Output Current (Bank) | 15A(Max) | 16A(Max) |
Maximum Output Current (Total) | 30A(Max) | 32A(Max) |
Breakers | 2 x 16A UL489 Breaker | 2 x 16A UL489 Breaker |
Metering | Bank Level Current Monitoring (Via EC1000 Energy Box) | Bank Level Current Monitoring (Via EC1000 Energy Box) |
Outlet Switching | None | None |
Environment Sensor Ports | 0 | 0 |
Metering Accuracy | Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% | Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Physical Properties | ||
Dimensions (L x W x H) | 130.00 x 4.04 x 4.40 cm (51.18 x 1.59 x 1.73 in.) |
130.00 x 4.04 x 4.40 cm (51.18 x 1.59 x 1.73 in.) |
Weight | 3.60 kg ( 7.93 lb ) | 3.60 kg ( 7.93 lb ) |
Power Cord Length | 1.6 m | 1.6 m |
Environmental | ||
Temperature (Operating / Storage) | 0–50°C / -20–60°C | 0–50°C / -20–60°C |
Humidity (Operating & Storage) | 0–80% RH, Non-Condensing | 0–80% RH, Non-Condensing |
Compliance | ||
EMC Verification | FCC, Others by Request | CE, C-Tick, Others by Request |
Safety Verification | PSE, Others by Request | TUV-CB, GOST, Others by Request |
Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |