The Aten PE0210S is a 10-outlet, 1U rack-mount power distribution unit (PDU) with IEC and NEMA outputs. It ensures efficient power distribution from a single plug, featuring surge protection and durable aluminum housing for longevity. Ideal for data centers, server rooms, and telecom equipment, this PDU provides unfiltered electrical pass-through and comes with a power cord and user instructions.
We Accept
Manufacture: Aten | Model: PE0210SG-AT-G
| Function | PE0210SA | PE0210SB | PE0210SG |
| Electrical | |||
| Nominal Input Voltage | 100-120 VAC | 100-240 VAC | 100-240 VAC |
| Maximum Input Current | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A (Max) |
| Input Frequency | 50-60 Hz | 50-60 Hz | 50-60 Hz |
| Input Connection | For A Plug: NEMA L5-20P For A2 Plug:NEMA 5-20P |
NEMA L6-20P | For G Plug: IEC-320 C20 For Z Plug: Chinese 16A |
| Input Power | 2400VA(Max); 1920VA(UL de-rated) |
4800VA(Max); 3840VA(UL de-rated) |
3840VA(Max) |
| Outlet Type | (10) NEMA 5-20R | (10) IEC 320 C13 | (10) IEC 320 C13 |
| Maximum Output Current (Outlet) | 20A Max (UL de-rated 16A Max) |
15A Max (UL de-rated 12A Max) |
10A (Max) |
| Maximum Output Current (Bank) | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A (Max) |
| Maximum Output Current (Total) | 20A Max (UL de-rated 16A Max) |
20A Max (UL de-rated 16A Max) |
16A (Max) |
| OPD(Overcurrent Protection Device) | Yes | Yes | Yes |
| Physical Properties | |||
| Dimensions (L x W x H) | 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
| Weight | 0.67 kg ( 1.48 lb ) | 0.67 kg ( 1.48 lb ) | 0.67 kg ( 1.48 lb ) |
| Power Cord Length | 10ft(12#) | 10ft(12#) | 10ft(3*2.5mm2) |
| Environmental | |||
| Temperature (Operating / Storage) | 0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
| Elevation (Operating / Storage) | 3000m | 3000m | 3000m |
| Compliance | |||
| EMC Verification | FCC Class A | FCC Class A | - |
| Safety Verification | UL | UL | LVD |
| Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. | ||