Sku: PE0212G-AT-G
Brand: ATEN
Category: KVM Over IP
Availability: On Order
On Order - These items are sourced upon request and may take longer to deliver. We will confirm availability once your order is received, as some products may occasionally be discontinued or unavailable.
Shipping Calculator
Find
The ATEN PE0212 Series Basic PDU provides 12 AC outlets with both IEC and NEMA socket configurations. Its space-saving 1U rack-mountable design allows for efficient use of space in server rooms. This PDU is ideal for use with servers, network devices, and telecom equipment, offering a practical solution for power distribution in any setup.
We Accept
Manufacture: Aten | Model: PE0212G-AT-G
| Function | PE0212A | PE0212B | PE0212G |
| Electrical | |||
| Nominal Input Voltage | 100-120 VAC | 100-240 VAC | 100-240 VAC |
| Maximum Input Current | 20A Max (UL de-rated 16A Max) |
20A (Max) (UL de-rated 16A Max) |
16A (Max) |
| Input Frequency | 50-60 Hz | 50-60 Hz | 50-60 Hz |
| Input Connection | For A Plug NEMA L5-20P For A2 Plug : NEMA 5-20P |
NEMA L6-20P | IEC-320 C20 |
| Input Power | 2400VA(MAX)? 1920VA(UL de-rated) |
4800VA(Max); 3840VA(UL de-rated) |
3840VA(Max) |
| Outlet Type | (12) NEMA 5-20R | (12) IEC 320 C13 | (12) IEC 320 C13 |
| Maximum Output Current (Outlet) | 20A (Max) (UL de-rated 16A Max) |
15A (Max) (UL de-rated 12A Max) |
10A (Max) |
| Maximum Output Current (Bank) | 20A (Max) (UL de-rated 16A Max) |
20A (Max) (UL de-rated 16A Max) |
16A (Max) |
| Maximum Output Current (Total) | 20A (Max) (UL de-rated 16A Max) |
20A (Max) (UL de-rated 16A Max) |
16A (Max) |
| OPD(Overcurrent Protection Device) | Yes | Yes | Yes |
| Physical Properties | |||
| Dimensions (L x W x H) | 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) |
| Weight | 0.63 kg ( 1.39 lb ) | 0.63 kg ( 1.39 lb ) | 0.63 kg ( 1.39 lb ) |
| Power Cord Length | 10ft(12#) | 10ft(12#) | 10ft(3×1.5mm2) |
| Environmental | |||
| Temperature (Operating / Storage) | 0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. |
| Elevation (Operating / Storage) | 3000m | 3000m | 3000m |
| Compliance | |||
| EMC Verification | FCC Class A | FCC Class A | - |
| Safety Verification | UL, other by request | UL, other by request | LVD, UL |
| Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. | ||